Fase offer several controllers to indicate class change indication in educational premises or for use as factory shift change indication amongst other uses.

Our basic class change controllers are the FASE/701/E and the FASE/701/EXT. These controllers are nearly identical, differing only in the number of class change alarms they offer per day. The FASE/701/E provides up to 20 alarms per day, whereas the FASE/701/EXT offers up to 60 alarms per day.

All other models are variations of these two controllers and have a suffix of either 'LP' or 'HP' - for example - FASE/701/E/LP.

If the time clock includes the 'LP' suffix then this is capable of driving upto 2 sounder circuits directly from the controller.

If the time clock includes the 'HP' suffix then this is capable of driving upto 2 sounder or bell circuits directly from the controller.

Click on the relevent controller below to download Consultant Specifications in Word format.

Can I not use a controller with the suffix 'LP' to power bell circuits?

No. Motorised bells are an inductive load which generate electical noise when ringing and inductive spikes when de-energised.

This noise and spikes can damage electronic compentents if not correctly managed. The controllers with the 'HP' suffix have relays and componets specifically designed to drive the motorised bells where the controllers with the 'LP' suffix do not. The 'HP' controllers must be used if driving motorised bells.